In the notebook MichToLigo, a homodyne detector was used to measure the quantum noise limited sensitivity. And that’s where squeezing was used to reduce the quantum noise. However, in the notebook MichelsonSensitivity, the command qnoised was used to measure the quantum noise limited sensitivity. Which one of these methods should we use to find the […]
Author: Harley Suchiang
While injecting a signal into the Michelson’s arms do we need to use fsig for the thickness of the lens and other lengths in and the X and Y arm.
I think we found a minor bug. When we try to join two spaces with a node and finesse throws an error saying Bug detected. ————————————————————– Error from Finesse (See ‘pykat.lastErrorKat’ for kat object): Bug detected! In function check_node_direction() of file kat_matrix_ccs.c at line 3508. Error message: Node n1_1 is connected to multiple components but […]